package node import ( "context" "fmt" "os" "os/signal" "path" "sync" "syscall" "github.com/pkg/errors" "github.com/prysmaticlabs/prysm/shared" "github.com/prysmaticlabs/prysm/shared/cmd" "github.com/prysmaticlabs/prysm/shared/debug" "github.com/prysmaticlabs/prysm/shared/event" "github.com/prysmaticlabs/prysm/shared/prometheus" "github.com/prysmaticlabs/prysm/shared/tracing" "github.com/prysmaticlabs/prysm/slasher/beaconclient" "github.com/prysmaticlabs/prysm/slasher/db" "github.com/prysmaticlabs/prysm/slasher/db/kv" "github.com/prysmaticlabs/prysm/slasher/detection" "github.com/prysmaticlabs/prysm/slasher/flags" "github.com/prysmaticlabs/prysm/slasher/rpc" "github.com/sirupsen/logrus" "gopkg.in/urfave/cli.v2" ) var log = logrus.WithField("prefix", "node") const slasherDBName = "slasherdata" // SlasherNode defines a struct that handles the services running a slashing detector // for eth2. It handles the lifecycle of the entire system and registers // services to a service registry. type SlasherNode struct { ctx *cli.Context lock sync.RWMutex services *shared.ServiceRegistry proposerSlashingsFeed *event.Feed attesterSlashingsFeed *event.Feed stop chan struct{} // Channel to wait for termination notifications. db db.Database } // NewSlasherNode creates a new node instance, sets up configuration options, // and registers every required service. func NewSlasherNode(ctx *cli.Context) (*SlasherNode, error) { if err := tracing.Setup( "slasher", // Service name. ctx.String(cmd.TracingProcessNameFlag.Name), ctx.String(cmd.TracingEndpointFlag.Name), ctx.Float64(cmd.TraceSampleFractionFlag.Name), ctx.Bool(cmd.EnableTracingFlag.Name), ); err != nil { return nil, err } registry := shared.NewServiceRegistry() slasher := &SlasherNode{ ctx: ctx, proposerSlashingsFeed: new(event.Feed), attesterSlashingsFeed: new(event.Feed), services: registry, stop: make(chan struct{}), } if err := slasher.registerPrometheusService(ctx); err != nil { return nil, err } if err := slasher.startDB(ctx); err != nil { return nil, err } if err := slasher.registerBeaconClientService(ctx); err != nil { return nil, err } if err := slasher.registerDetectionService(); err != nil { return nil, err } if err := slasher.registerRPCService(ctx); err != nil { return nil, err } return slasher, nil } // Start the slasher and kick off every registered service. func (s *SlasherNode) Start() { s.lock.Lock() s.services.StartAll() s.lock.Unlock() stop := s.stop go func() { sigc := make(chan os.Signal, 1) signal.Notify(sigc, syscall.SIGINT, syscall.SIGTERM) defer signal.Stop(sigc) <-sigc log.Info("Got interrupt, shutting down...") debug.Exit(s.ctx) // Ensure trace and CPU profile data are flushed. go s.Close() for i := 10; i > 0; i-- { <-sigc if i > 1 { log.Info("Already shutting down, interrupt more to panic", "times", i-1) } } panic("Panic closing the beacon node") }() // Wait for stop channel to be closed. <-stop } // Close handles graceful shutdown of the system. func (s *SlasherNode) Close() { s.lock.Lock() defer s.lock.Unlock() log.Info("Stopping hash slinging slasher") s.services.StopAll() if err := s.db.Close(); err != nil { log.Errorf("Failed to close database: %v", err) } close(s.stop) } func (s *SlasherNode) registerPrometheusService(ctx *cli.Context) error { service := prometheus.NewPrometheusService( fmt.Sprintf(":%d", ctx.Int64(flags.MonitoringPortFlag.Name)), s.services, ) logrus.AddHook(prometheus.NewLogrusCollector()) return s.services.RegisterService(service) } func (s *SlasherNode) startDB(ctx *cli.Context) error { baseDir := ctx.String(cmd.DataDirFlag.Name) clearDB := ctx.Bool(cmd.ClearDB.Name) forceClearDB := ctx.Bool(cmd.ForceClearDB.Name) dbPath := path.Join(baseDir, slasherDBName) cfg := &kv.Config{} d, err := db.NewDB(dbPath, cfg) if err != nil { return err } clearDBConfirmed := false if clearDB && !forceClearDB { actionText := "This will delete your slasher database stored in your data directory. " + "Your database backups will not be removed - do you want to proceed? (Y/N)" deniedText := "Database will not be deleted. No changes have been made." clearDBConfirmed, err = cmd.ConfirmAction(actionText, deniedText) if err != nil { return err } } if clearDBConfirmed || forceClearDB { log.Warning("Removing database") if err := d.ClearDB(); err != nil { return err } d, err = db.NewDB(dbPath, cfg) if err != nil { return err } } log.WithField("database-path", baseDir).Info("Checking DB") s.db = d return nil } func (s *SlasherNode) registerBeaconClientService(ctx *cli.Context) error { beaconCert := ctx.String(flags.BeaconCertFlag.Name) beaconProvider := ctx.String(flags.BeaconRPCProviderFlag.Name) if beaconProvider == "" { beaconProvider = flags.BeaconRPCProviderFlag.Value } bs, err := beaconclient.NewBeaconClientService(context.Background(), &beaconclient.Config{ BeaconCert: beaconCert, SlasherDB: s.db, BeaconProvider: beaconProvider, AttesterSlashingsFeed: s.attesterSlashingsFeed, ProposerSlashingsFeed: s.proposerSlashingsFeed, }) if err != nil { return errors.Wrap(err, "failed to initialize beacon client") } return s.services.RegisterService(bs) } func (s *SlasherNode) registerDetectionService() error { var bs *beaconclient.Service if err := s.services.FetchService(&bs); err != nil { panic(err) } ds := detection.NewDetectionService(context.Background(), &detection.Config{ Notifier: bs, SlasherDB: s.db, BeaconClient: bs, ChainFetcher: bs, AttesterSlashingsFeed: s.attesterSlashingsFeed, ProposerSlashingsFeed: s.proposerSlashingsFeed, }) return s.services.RegisterService(ds) } func (s *SlasherNode) registerRPCService(ctx *cli.Context) error { var detectionService *detection.Service if err := s.services.FetchService(&detectionService); err != nil { return err } port := ctx.String(flags.RPCPort.Name) cert := ctx.String(flags.CertFlag.Name) key := ctx.String(flags.KeyFlag.Name) rpcService := rpc.NewService(context.Background(), &rpc.Config{ Port: port, CertFlag: cert, KeyFlag: key, Detector: detectionService, SlasherDB: s.db, }) return s.services.RegisterService(rpcService) }